10 kW / 10 kWh backup power kit

For a house where a water heater, cooker or air conditioner run at the same time, but outages are short. Roughly 3–6 hours of backup runtime at an average load of 1.50–3.00 kW.

[01] — Your solution

The right reserve. The exact configuration.

The 10 kW inverter sets the maximum simultaneous load. The 10 kWh battery provides the energy reserve, with about 9.0 kWh available to your appliances.

See what this power rating can handle on the 10 kW backup power page.

Runtime by load

Average loadAutonomy
0.5 kW≈ 18.0 h
1 kW≈ 9.0 h
2 kW≈ 4.5 h
3 kW≈ 3.0 h
5 kW≈ 1.8 h
8 kW≈ 1.1 h

Estimate based on 90 % of available battery capacity. Actual runtime depends on how your appliances are used and on conversion losses.

[02] — Configuration examples

FoxESS equipment for 10 kW / 10 kWh

  • Fox ESS P100-10-H — 10 kW / 10.24 kWh, equipment from UAH 128,940 excl. VAT
  • Fox ESS KH10 + EP6 Plus × 2 — 10 kW / 11.52 kWh, 4 MPPT for solar panels
Power10 kWCapacity10.24 kWh

Energy storage system

Fox ESS P100-10-H

10 kW / 10.24 kWh all-in-one energy storage system

  • 10 kW
  • 10.24 kWh
  • 1 phase

Suitable for: apartments, houses

Contact us for availability
UAH 128,940 / pc excl. VATDetails

Single-phase hybrid inverter

Fox ESS KH10

10 kW single-phase hybrid inverter, 4 MPPT

  • 10 kW
  • 1 phase
  • 4 MPPT
In stock
UAH 82,720 / pc excl. VATDetails

LiFePO₄ battery

Fox ESS EP6 Plus

192 V / 5.76 kWh high-voltage LiFePO₄ battery with heating

  • 5.76 kWh
  • 192 V
  • up to 23.04 kWh
Contact us for availability
Price on requestDetails
Request a price

This is a configuration for custom selection, not a stock kit. The final configuration, compatibility, VAT and installation are agreed in the quote.

[04] — Questions

Answers before you choose

How many hours will a 10 kW / 10 kWh kit run?

It depends on the average load. At 1.50 kW, about 6 hours; at 3.00 kW, about 3. The calculation assumes 90 % of the battery capacity is available.

Can I run appliances totalling 10 kW at the same time?

Yes, within the inverter's rated power. For pumps, compressors and air conditioners, we account for inrush currents and build in a margin.

Can the capacity be increased later?

Yes: up to three P100 systems can run in parallel, and the high-voltage batteries expand in modules. We choose the configuration with room for expansion.

[→] — Request

10 kW / 10 kWh kit for your site

Leave your contact details — we will clarify what must keep working during outages and prepare a commercial proposal.

Photos of the distribution board, a list of appliances or a roof plan are easier to send by e-mail. Planning an installation? Fill in the technical brief — for a home or a business.