A 5–6 kW system is the most common choice for an apartment or small house with a single-phase supply. It is enough to keep the fridge, gas boiler, lighting, internet, TV and pump running during outages.

[01] — Your solution

What a 5 kW system can handle

The simplest option is the Fox ESS P100-6-H all-in-one system: a 6 kW inverter and a 10.24 kWh battery in a single enclosure. Alternatively, a separate H1 hybrid inverter with expandable high-voltage batteries.

  • Fridge and freezer
  • Gas boiler and circulation pump
  • LED lighting for the whole home
  • Router, laptops, TV
  • Booster pump station or borehole pump up to 1 kW
  • One electric hob ring or a microwave, but not at the same time as the pump

We check the inrush currents of pumps and compressors separately, as they determine how much power headroom the inverter needs.

[02] — Energy reserve

Recommended configurations

The inverter determines what can run at the same time; the battery determines for how long. Runtime is given for an average load of 15–30 % of the inverter's rated power.

[03] — Equipment

Suitable for this solution

Power6 kWCapacity10.24 kWh

Energy storage system

Fox ESS P100-6-H

6 kW / 10.24 kWh all-in-one energy storage system

  • 6 kW
  • 10.24 kWh
  • 1 phase

Suitable for: apartments, houses

In stock
UAH 115,850 / pc excl. VATDetails
Power5 kWCapacity5.12 kWh

Energy storage system

Fox ESS P50-5-H

An all-in-one 5 kW / 5.12 kWh energy storage system

  • 5 kW
  • 5.12 kWh
  • 1 phase

Suitable for: apartments, houses

In stock
UAH 72,800 / pc excl. VATDetails

LiFePO₄ battery

Fox ESS EP6 Plus

192 V / 5.76 kWh high-voltage LiFePO₄ battery with heating

  • 5.76 kWh
  • 192 V
  • up to 23.04 kWh
Contact us for availability
Price on requestDetails
Request a price

[04] — Questions

Answers before you choose

Can a 5 kW system run an electric cooker?

One 1–2 kW hob ring together with basic appliances, yes. The whole cooker with the oven at the same time, no: that needs a 8–10 kW system.

How many hours will a 5 kW + 10 kWh kit run?

At an average load of 0.75–1.5 kW (fridge, boiler, lights, internet and an occasional pump), roughly 6–12 hours.

What if I have a three-phase supply?

A single-phase system can be connected to one phase, with the required circuits moved onto it. If you need backup on all phases or have three-phase equipment, choose a three-phase inverter from 12 kW.

[→] — Request

Get a solution for your site

Leave your contact details — we will clarify what must keep working during outages and prepare a commercial proposal.

Photos of the distribution board, a list of appliances or a roof plan are easier to send by e-mail. Planning an installation? Fill in the technical brief — for a home or a business.