The 5 kW Dyness D5.0K-LS single-phase hybrid inverter works with the grid, solar panels and 48 V low-voltage batteries (40-60 V range), with charge and discharge current up to 120 A. It suits an apartment or a house with a single-phase supply.
It accepts up to 10 kW of solar panels on 2 MPPT trackers, one string per MPPT. The back-up output delivers up to 5500 VA continuously and up to 10000 VA for 10 s, with switchover to back-up in under 4 ms. A generator can be connected. IP 66 enclosure, operating temperature -30…+60 °C, weight 17 kg. Up to 16 inverters can run in parallel.
Features
Solar panels up to 10000 W
2 MPPT trackers
Battery voltage 40-60 V
Back-up switchover under 4 ms
IP 66 protection rating
Operating temperature -30…+60 °C
Generator connection
Up to 16 inverters in parallel
Technical specifications
Battery type
Lead-acid or Li-ion
Nominal battery voltage, V
48
Battery voltage range, V
40-60
Max. charge / discharge current, A
120
Max. charge / discharge power, W
5000/5500
Max. PV input power, W
10000
Max. PV voltage, V
600
PV operating voltage range, V
50-550
Start-up voltage, V
60
MPPT range at nominal power, V
150-500
Nominal PV voltage, V
380
MPPTs / strings
2/1+1
Max. input current per MPPT, A
20/20
Max. short-circuit current per MPPT, A
27/27
Rated AC power
5000 VA
Max. AC power to grid
5500 VA
Max. power from grid
10000 VA
Nominal grid voltage
220/230/240 V, L/N/PE
Grid frequency, Hz
50/60
Max. AC current to grid, A
25
Max. AC current from grid, A
40
Power factor
0.8 leading to 0.8 lagging
Output THDi
<3% (at nominal power)
Back-up output: max. continuous power
5500 VA
Back-up output: peak power
10000 VA, 10 s
Back-up output: max. current, A
25
Back-up switching time
<4 ms
Back-up output THDv
<3% (linear load)
AC input (generator): nominal / max. power, VA
5000/10000
AC input (generator): max. current, A
40
Max. efficiency
97.6%
European efficiency
96.5%
Built-in protection
anti-islanding, PV insulation resistance detection, PV reverse polarity protection, residual current monitoring, AC overcurrent and overvoltage protection, PV DC switch
Surge protection
Type III (DC), Type III (AC)
Communication interfaces
BMS (CAN), EMS (RS485, Modbus), meter (RS485), DRED/RCR (DI), remote shutdown (DI), dry contact (DO), Wi-Fi, LAN
Display
LED, LCD, app
Parallel operation
up to 16 inverters
Operating temperature
-30…+60 °C
Relative humidity
0~100%
Max. altitude, m
3000
Ingress protection
IP 66
Cooling
Natural convection / intelligent air cooling
Installation
Wall-mounted
Dimensions (W×H×D), mm
501×586×193
Weight, kg
17
Grid standards
IEC 61727, IEC 62116, EN 50549-1, NRS 097, G98, G99
Dyness manufacturer data (D3.0K–D8.0K-LS user manual, version 20240710-V1). A manager will confirm the compatibility of a specific battery and the warranty terms before you order.
Which batteries are compatible with this inverter?
48 V low-voltage batteries (40–60 V range): lithium-ion with a BMS that communicates with the inverter over CAN, or lead-acid. We check the compatibility of a specific battery model before you order.
Can solar panels be connected later?
Yes. The inverter can run with just the grid and a battery, and up to 10 kW of panels on 2 MPPTs can be added later.
How many hours will the system run during a power outage?
It depends on battery capacity and average load. Use the autonomy calculator or send a request and we will calculate it for your list of appliances.
How do I get a price?
Send a request or call us: we'll give you the equipment price together with the installation estimate. Cables, switchgear and protection are selected after a site survey or from a photo of your distribution board.
[→] — Request
Tell us about your property
We will select the configuration, check compatibility and calculate the cost with installation.
Photos of the distribution board, a list of appliances or a roof plan are easier to send by e-mail. Planning an installation? Fill in the technical brief — for a home or a business.